dc.creator | Dowrick, D. J. | |
dc.date | 1986-06-30 | |
dc.date.accessioned | 2020-01-13T11:20:55Z | |
dc.date.available | 2020-01-13T11:20:55Z | |
dc.identifier | https://bulletin.nzsee.org.nz/index.php/bnzsee/article/view/843 | |
dc.identifier | 10.5459/bnzsee.19.2.143-152 | |
dc.identifier.uri | https://repo.nzsee.org.nz/xmlui/handle/nzsee/1597 | |
dc.description | This paper reviews experimentally determined hysteresis loops for timber structures, including moment-resisting joints with (i) steel and (ii) plywood side plates, (iii) shear walls clad with various materials, and (iv) push-pull tests on various connection details. The paper compares bending and push-pull hysteresis loops for nailed steel side-plate joints. An attempt is made to classify the above hysteretic behaviour for analytical purposes, and the available computer models are reviewed for applicability to these hysteresis shapes. | en-US |
dc.format | application/pdf | |
dc.language | eng | |
dc.publisher | New Zealand Society for Earthquake Engineering | en-US |
dc.relation | https://bulletin.nzsee.org.nz/index.php/bnzsee/article/view/843/818 | |
dc.rights | Copyright (c) 1986 D. J. Dowrick | en-US |
dc.rights | https://creativecommons.org/licenses/by/4.0 | en-US |
dc.source | Bulletin of the New Zealand Society for Earthquake Engineering; Vol 19 No 2 (1986); 143-152 | en-US |
dc.source | 2324-1543 | |
dc.source | 1174-9857 | |
dc.title | Hysteresis loops for timber structures | en-US |
dc.type | info:eu-repo/semantics/article | |
dc.type | info:eu-repo/semantics/publishedVersion | |
dc.type | Article | en-US |