    Advances in Floor Diaphragm In-Plane Modelling Using Truss Elements

    Thumbnail
    Download
    PDF (990.7Kb)
    Date
    2021-04-14
    Authors
    Alizadeh, Saeid
    MacRae, Gregory
    Bull, Des
    Clifton, Charles
    Metadata
    Show full item record
    Abstract
    Different methods to model building floor diaphragm in-plane stiffness with truss elements are compared to identify the method most suitable for analysis in design. The methods considered include (i) Elastic truss, (ii) Diagonal compression-only truss members with compression/tension orthogonal members, (iii) Diagonal compression-only truss members, considering reinforcement as orthogonal members in tension and concrete in compression, (iv) Diagonal compression-only truss members with tension-only orthogonal members, (v) Diagonal compression-only truss members with compression/tension orthogonal members based on Section C5 of “The Seismic Assessment of Existing Buildings” recommendations (2017) and (vi) Nonlinear truss considering likely properties of the steel and concrete material. The truss elements were placed in square blocks and are compared with FEM in terms of global stiffness and diaphragm internal load path. It was found that, truss model with diagonal compression-only and orthogonal compression/tension elements (representing un-cracked diaphragm properties), and truss model with diagonal compression-only and orthogonal reinforcement tension/concrete compression members (representing cracked diaphragm properties) satisfied the criteria of providing simple outputs usable for design and reasonable accuracy. They were recommended for use in diaphragm design.
    URI
    https://repo.nzsee.org.nz/handle/nzsee/2391
    Published in
    • Proceedings of the 2021 New Zealand Society for Earthquake Engineering Annual Technical Conference

    Contact Us | Send Feedback
     

     

    Browse

    Entire RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    Login

    Contact Us | Send Feedback